2 × SYBR Green qPCR Master Mix (High ROX)

คุณสมบัติสินค้า:

SKU :

Quantity

แบรนด์ : Servicebio

Share

Product Information

Product Name

Cat. No.

Spec.

2×SYBR Green qPCR Master Mix (High ROX)

G3322-01

1 mL

G3322-05

5×1 mL

G3322-15

15×1 mL


Product Description/Introduction

2×SYBR Green qPCR Master Mix (High ROX) is a ready-to-use solution optimized for quantitative real-time PCR and two-step real-time RT-PCR. The master mix includes Hot Start Taq DNA polymerase and dNTPs in an optimized PCR buffer to ensures PCR specificity and sensitivity. The SYBR Green I intercalating dye allows for DNA detection and analysis without using sequence-specific probes. Only template and primers need to be added. The use of 2×SYBR Green qPCR Master Mix (High ROX) in real time PCR ensures reproducible, sensitive and specific quantification of genomic, plasmid, viral and cDNA templates.


Storage and Shipping Conditions

Ship with wet ice. Store at -20°C without light, valid for 12 months. Avoid freeze-thaw cycles. After thawing, it can be stably stored at 4 for one month without light.


Product Contents

Component

G3320-01

G3320-05

G3320-15

2×SYBR Green qPCR Master Mix (Low ROX)

1 mL

5×1 mL

15×1 mL

Manual

One copy


Assay Protocol / Procedures

Before starting

1. Real Time PCR amplification instrument;

2. Special reaction tube or reaction plate for experiment;

3. PCR primers (reference primer design principles);

4. Micropipette and autoclaving-tips;


Procedures

1. Recommended PCR reaction systems 

Component

20 μL rxn

50 μL rxn

Final Concentration

2×SYBR Green qPCR Master Mix (Low ROX)

10 μL

25 μL

Forward Primer (10 μM)a

0.4 μL

1 μL

0.2 μM

Reverse Primer (10 μM)a

0.4 μL

1 μL

0.2 μM

Templateb

Variable

Variable

as required

Nuclease-Free Water

Add to 20 μL

Add to 50 μL


a. Usually, a good amplification effect can be obtained with the final concentration of 0.2 μM. When the reaction performance is poor, the primer concentration can be adjusted in the range of 0.2-1.0 μM.

b. The amount of template added varies depending on the number of copies of the target gene, and the appropriate amount of template addition is studied by gradient dilution. The best addition amount of template DNA in the 20 μL reaction system was less than 100 ng. When the cDNA (RT reaction solution) of RT-PCR reaction was used as template, the addition amount should not exceed 10% of the final qPCR volume.

3. PCR reaction program (can be adjusted appropriately according to the instruments)

A. Two-step process*

B. Three-step process*

Stage

Step

Cycles

Temperature

Time

Stage

Step

Cycles

Temperature

Time

Stage 1

Predegeneration

1

95

30 sec

Stage 1

Predegeneration

1

95

30 sec

Stage 2

Degeneration

40

95

15 sec

Stage 2

Degeneration

40

95

15 sec

Annealing-Extension

60

30 seca

Annealing

55-65

10 sec

extension

72

30 seca

Stage 3

Melting curve

1

Instrument default Settings

Stage 3

melting curve

1

Instrument default Settings

*: If amplification specificity needs to be improved, two-step procedure or annealing temperature can be used; To improve the amplification efficiency, a three-step procedure or extension time can be used.

a: For fluorescence signal collection, please set the experimental procedure according to the instruction manual of the instrument.

Note

1. Mix gently upside down before use. Do not swirl and shake to avoid bubbles. Mix the reagents well before using.

2. Reagents should be placed on ice when preparing reaction solution.

3. The product contains fluorescent dye SYBR Green, so strong light should be avoided when preparing PCR reaction solution.

4. Please using new disposable tips for the preparation and packaging of the reaction solution to avoid contamination between samples.

5. Avoid repeated freeze-thawing of Master Mix and try to use it within one month after thawing.

Compatible instruments

Brand of PCR machine

G3320

(None ROX)

G3321

(Low ROX)

G3322

(High ROX)

ABI Thermo life

PikoRealTM Cycler

7500/7500 Fast,

ViiA 7 QuantStudio series

5700/7000/7300/7700/7900/

7900HT/7900 HT Fast,StepOne,StepOne Plus

Stratagene


Mx3000P®/3005P/4000


Bio-Rad

All series



Eppendorf

Realplex 2s,Mastercycler®ep realplex



IIIumina

Eco QPCR



Cepheid

SmartCycler®



Qiagen Corbett

Rotor-Gene® series



Roche

LightCycler series



Takara

Thermal Cycler Dice series



Analytikjena

qTOWER series



qTOWER

LineGene series



Primer design principles

1. The length of amplification product is recommended to be between 80-300 bp;  

2. Primer length: 18-25 bp;  

3. The content of base G+C in primers should be between 40%-60%;  

4. The Tm value difference between forward primers and reverse primers is less than 2, and the Tm value between 58-62 is the best;  

5. Randomness of base distribution;  

6. Primers had better not contain self-complementary sequences, otherwise they will form a secondary hairpin structure;  

7. There should be no more than 4 complementary or homologous bases between two primers, otherwise primer dimer will be formed, especially complementary overlap at the 3' end;  

8. The 3' terminal base of the primer is suggested to be G or C;  

9. No other non-specific products were found in NCBI comparison results.

Trouble-Shooting

For Research Use Only!

Problem description

Possible reasons

Solutions

At the end of the reaction, no amplification curve appeared or CT value appeared too late

The template concentration is too low

Repeat the experiment to reduce the template dilution multiple, and start from the highest concentration when the sample concentration is unknown

Template degradation

The template was prepared again and the experiment was repeated

There are PCR inhibitors in the system

Generally, the template is carried in, the dilution ratio of the template is increased or the template with high purity is reprepared and repeated

Primers may degrade

Primers that have not been used for a long time should first be tested for integrity by PAGE electrophoresis to rule out the possibility of degradation

Low amplification efficiency

Increase the primer concentration, try a three-step amplification procedure, or redesign the primer

The amplification product is too long

The amplification product length was controlled in the range of 80-300 bp

The blank control shows the signal

Reaction system pollution

Firstly, the blank control water should be replaced. If the same situation still occurs, the primers, aspirators and PCR tubes should be replaced or a new Master Mix should be started. The reaction system is prepared in a super clean table to reduce aerosol pollution

Non-specific amplification such as primer dimers appears

Generally, it is normal for the amplification products to appear in blank control after 35 cycles, which should be analyzed with the melting curve.

Redesign primer, adjust primer concentration or optimize PCR reaction procedure

The melting curve has multiple peaks

Primer design is poor

The new primer was re-designed according to the primer design principles

Primer concentration is too high

Reduce primer concentration appropriately

There is genomic contamination in cDNA template

The extracted RNA solution is digested using DNA enzymes, such as dsDNase, to remove genomic contamination, or to design transintron primers

Poor reproducibility of experiments

The error of adding sample is large

The use of accurate pipette, with high quality suction head accurate pipette;

High dilution template, adding large volume template to reduce sampling error;

The reaction volume of qPCR was enlarged

The template concentration is too low

Repeat the experiment to reduce the dilution times of the template

Temperature deviation at different locations of the qPCR instrument

Calibrate the qPCR instrument regularly

The amplification curve is not smooth

Fluorescence signal is too weak, produced after system correction

Ensure that the dyes premixed in the Master Mix are not degraded;

Replace fluorescent signal to collect better qPCR consumables

Amplification curve breaks or slips

The template concentration was higher and the baseline endpoint value was greater than the CT value

The baseline endpoint (Ct value -3) was reduced and the data were reanalyzed

Amplification curves of individual Wells suddenly dropped sharply

There are bubbles in the reaction tube

Ensure that MIX is completely dissolved, and do not swirl and oscillate evenly;

After the sample is added, the bubbles are removed by centrifugation with light elastic.

The pre-denaturation time was extended to 10 min to remove the bubbles

 

https://www.servicebio.com/goodsdetail?id=4268