Product Information
Product Name | Cat.No. | Spec. |
Environment Friendly GD Fixative Solution
| G1111-100ML | 100 mL |
G1111-10ML | 10 mL |
Description
In histopathology, the tissue must be promptly and effectively fixed before subsequent embedding and sectioning can be completed. Organization fixed role is to maintain the inherent morphology and structure of organization, cell, prevent bacteria corrosion and tissue autolysis, save the inherent material inside the cell, the cell protein coagulation, as far as possible to reduce or end of endogenous and exogenous enzyme reaction, keep the cell or tissue basically like living material, also can make the organization hardening, easy to repair the cut of the organization. For certain infectious specimens, can prevent the spread of disease; Preserve the gross specimen. Finally, fixation can enhance the effect of staining. Formaldehyde is the most commonly used fixative, with strong penetration, uniform fixation, tissue shrinkage and appropriate hardness, which is suitable for the fixation of most tissue samples.
This product is environmentally friendly GD fixation solution, specially used for muscle tissue fixation. Compared with conventional fixation solution, this solution can improve the problem of muscle tissue lobes and obtain high-quality muscle tissue slices. The main ingredients of this product are formalin, glacial acetic acid and absolute ethanol.
Storage and Handling Conditions
Transport at room temperature; Store in a cool and dry place, away from direct sunlight, valid for 24 months.
Assay Protocol
The freshly harvested muscle tissue was quickly put into the fixation fluid, and the ratio of tissue to fixation fluid was not less than 1:10.
It can be fixed at room temperature for about 6-24 h.
Note:
1. Use the product in a well-ventilated environment with proper protection to avoid inhalation.
2. Please tighten the cap in time after use to prevent volatile active ingredients.
3. For your safety and health, please wear a lab coat and disposable gloves when operating.