Tissue Homogenizer Low Temperature (-50, Freezing Chamber)
Brand:Servicebio
Spec.:(-50, Freezing Chamber)
Product Introduction
SWE-FP is a newly upgraded low-temperature homogenizer, which can reach a temperature as low as -50 in the chamber and also equipped with a freezing chamber.Adopt high-speed reciprocating motion of the vertical shaking system, the frozen sample in the grinding tube collides with the grinding bead, and the resulting grinding shear force and impact force completely break down the tissue. Up to 192 samples can be processed simultaneously in one minute, making it a dedicated device that meets the requirements of rapid processing of multi-sample.
Product Features
1. Slider drive, no wear shaft, noise stability and durability;
2. Equiped with low temperature freezing chamber. It can meet the needs of sample storage, electrophoresis, membrane transfer and other low-temperature experiments
3. Imported compressor,lowest cooling temperature of -50,low temperature grinding throughout the process,reducing degradation of proteins and RNA.
4. Up to 192 samples can be processed simultaneously in 1 minute (24 samples can be processed with standard),efficiently and effectively completing sample grinding with high throughput.
5. Multiple adapters to choose.
Technical Parameters
1. Dimensions:Length 650mm,Width 420mm,Height 430mm
2. Weight:54 kg
3. Screen size:5 inches
4. Temperature:-50
5. Temperature control precision:±1
6. Working time:Runtime0-9999s,pausetime0-999s,andruntimes1-99times
Parameters Comparison
Cat. No. | SWE-FP |
Operating mode | The vertical shaking system moves back and forth at high speed. |
Temperature | -50 |
Temperature control precision | ±1 |
Standard spec. | 24*2 mL |
Maximum sample volume | 192 pcs |
Adapter specification | 24x0.5mL.24x2mL.48x2mL. 32x2mL.60x2mL.96x2mL. 12x5mL.10x10mL.4x30mL(steel can). 6x5mL(steel can).8x15mL(steel can) 2x50mL(steel can).96x2mL(2pcs 96-deep well plate) |
Freezing chamber | YES |
Adapter fixing method | Nut |
Working time | 0-99min99s |
Dimensions | 650*420*430mm |
Screen size | 5 inches |
Emergency stop button | YES |
Electromagnetic safety lock | Screen click control with automatic power-off unlocking. the cover cannot be opened during operation until the grinding program ends, fully protected. |
Maximum feeding size | No requirements, adjustable according to the adapter. |
Weight | 54kg |
Power parameters | 200-240VAC,50-60 Hz,500 W |
Cooling method | Compressor cooling |
Transport screws | Yes (2 at the bottom) |
Advantages | Lower cooling temperature can reach -50. low temperature freezing chamber, Protects samples and meets low-temperature needs for Western Blot experiments, electrophoresis, and transfer membranes. |
Unboxing and Installation
Remove the high-speed low-temperature tissue grinder from the packaging box and place it in a suitable location. Confirm that all components are complete.
Use the wrench provided in the accessories to remove the two fastening screws at the bottom of the instrument. (Before the first grinding operation, make sure to remove the fastening screws.)
Place the machine on a level and flat laboratory bench to prevent vibrations during operation.
Let it stand for 10 hours to ensure the coolant is in place. Connect the power supply (200-240V) and turn on the power switch at the back of the grinder.
Turn on the compressor cooling switch and wait for 10-15 minutes. Observe if the temperature in the grinding chamber reaches the set temperature.
6.If the temperature reaches the set temperature, install the adapter and nut correctly, then cover the top and start the machine.
Sample Preparation
The adapter can be used to grind 96 samples simultaneously in a 96-well plate. The adapter includes a base that can hold a 96-well plate, a top cover, and a locking nut.
Take the samples to be ground and place them in the grinding tubes. It is recommended to use no more than 100mg of sample. Add the corresponding extraction solution, ensuring that the total volume of the sample and extraction solution is within half of the overall volume. Add a few appropriately sized grinding beads. To ensure grinding efficiency and quality, for larger volume samples, it is recommended to cut them into smaller pieces using scissors.
Unscrew the locking nut and remove the top cover. Place the grinding tubes into the adapter, then attach the top cover and tighten the locking nut in a clockwise direction. (The placement of the tubes should follow the principles of symmetry and balance.)
Operation Steps
Plug the power cord of the grinder into a grounded 220V power outlet, and turn on the power switch at the back of the grinder.
After the startup interface is displayed, wait for about 5 seconds to enter the main operating interface.
Once the grinder is turned on, the cooling system starts running. Place the grinding tubes containing the samples, tighten the adapter, and cover the top of the grinder.
Set the operating frequency, time, and number of cycles. Click the "Temperature Selection" button to choose the temperature mode and set the desired temperature for the grinding chamber or the cooling platform.
Click the start button to begin the grinding process. The instrument will automatically stop once the timer reaches zero.