Low-temperature High-speed Centrifuge

คุณสมบัติสินค้า:

SKU : SLX-1024F

หมวดหมู่ : 12. Lab Equipment Centrifuge Servicebio

แบรนด์ : Servicebio

Share

Low-temperature High-speed Centrifuge
Maintain a low temperature of 4°C continuously for a long time at a speed of 12000 rpm
 
 

Product Introduction

The low-temperature centrifuge is widely used in various fields such as biology, medicine, agriculture, and chemical industry, lt is an instrument that utilizes centrifugal force to perform gravity-based fractionation of samples. The maximum speed of this machine is n=12000rpm, and the centrifugal force is RCF=13684xg. This low-temperature centrifuge ensures that the samples do not heat up during centrifugation, providing optimal protection for the samples.

 


Product Features

True low temperature, centrifuge without heating up

Truly protect samples, reduce RNA/protein degradation, and achieve better experimental results

1. Unsymmetrical balancing monitoring system: if the sample is unsymmetrically placed and unbalanced, the instrument will automatically stop centrifuging.

2. Compatible with various rotors: suitable for 1.5/2mL (standard), 5mL and 10mL centrifuge tubes.

 


Working Environment

Power Parameters

200-240VAC, 50-60Hz, 700W; power voltage fluctuation does not exceed 10% of the rated power voltage.

Room Temperature

5-40

Relative Humidity

Maximum 80%

Operating Location

Indoor use

Altitude

Up to 2000 meters

Technical Parameters

Dimensions

530×355×268 mm

Weight

45 kg

Screen Size

5 inches

Temperature Control Accuracy

±2

Operating Time

1-99 minutes

Operation Parameters

Operating Mode

Continuous

Time Setting

1-99 min

Balancing Monitoring

Gyroscope

Refrigeration system

SECOP Compressor Cooling 

Temperature Range

-20 - Room Temperature

Temperature Efficiency

Specimens at room temperature go in (centrifuge for 10 minutes) and come out at 4

Rotor Capacity

[1.5mL / 2mLx24] [5mLX12] [10mLX6]

Rotor Replacement

Quick-change mode: Only requires a dedicated wrench for removal and installation

Rotor Removal

Can be removed as a whole without opening the lid, to prevent the dispersion of specimen gas molecules

Specimen safety

Equipped with multiple sealing rings to prevent dispersion contamination

Interface Operation

Full touch screen interface, can be operated with gloves

Machine Safety

Double lock mechanism, and equipped with manual door opening mechanism during power failure

Status Indicator

LED strip status indicator, displays real-time working status

Software Functions

[Quick cooling setting] [Real-time temperature monitoring] [User program memory (up to 10 sets)] [Real-time parameter adjustment] [Gyroscope balancing detection] [Real-time monitoring of motor overvoltage, undervoltage, blockage, and overheating, with alarms and automatic shutdown]

 


Product Structure

image.png 

 


Operation Instruction

1. Unpacking and Installation

1) Remove the low-temperature centrifuge from the packaging box and place it in a suitable location, ensuring all components are complete;

2) Place the machine on a flat and level experimental table to prevent vibration during operation;

3) Let it stand for 10 hours to ensure the coolant is in place, connect the power supply (200-240V), and turn on the power switch at the back of the low-temperature centrifuge;

4) Turn on the instrument power switch, wait for 10-15 minutes, and observe if the temperature inside the centrifuge chamber reaches the preset temperature;

5) If the temperature reaches the preset temperature, the machine is ready for use

 

2. Operation Interface

image.png

1) Open door button,Opens the centrifuge lid

2) Start/Stop button.Starts and stops centrifugal separation

3) Set speed.The speed can be displayed in terms of centrifugal force (xg) or revolutions per minute (rpm). The current centrifuge is set to display rpm and xg. Click on the centrifugal force (or speed value) to modify the parameters, input the desired value for one, and the other will automatically adjust accordingly.

4) .Set time.Input the required parameter values in minutes (range: 1-99) and seconds (range: 0-59)

5) .Instant release button.Instant centrifugal separation.Press and hold the button to start centrifugation, release to stop centrifugation

6) Set temperatureAdjust the temperature parametersRange: -20 to room temperature

7) Speed up/slow downRange: 1-10 (the larger the number, the slower the speed)

 

Gear

1

2

3

4

5

6

7

8

9

10

Acceleration Time/s

20

25

30

35

40

45

50

55

60

70

Deceleration Time/s

20

25

30

35

40

45

50

60

70

80

8) Parameters.View 10 sets of parameter values in the background

9) Rapid cooling button.Click to enter rapid cooling mode

 


3. Operation Steps

image.png

1) Plug the power cord of the low-temperature centrifuge into a 220V power outlet with grounding protection and turn on the power switch at the back of the low-temperature centrifuge;

2) After the startup interface is displayed, wait for about 5 seconds to enter the main operation interface;

3) After the low-temperature centrifuge is turned on, the refrigeration system starts to operate. Place the centrifuge tubes symmetrically into the rotor and cover the rotor lid. Then close the top cover of the centrifuge machine;

4) Set the centrifugal force (or speed value), time, temperature, acceleration, and deceleration;

5) Click the button image.png to start the centrifugation process. The instrument will automatically stop after the countdown reaches zero.

 


4. Parameter Settings

image.png 

The instrument has 1 set of preset parameters, with a total of 10 sets of parameters, each of which can be edited.

For example, click on image.png to enter the parameter setting interface, select the centrifugal force (or speed value), acceleration, deceleration, and time for modification. After the modification is completed, click "Save" to save the corresponding parameters.

Click on image.png button to start the device. The touchscreen will countdown according to the set time. After the countdown is complete, the centrifugation ends, and the instrument automatically stops. Wait for the low-temperature centrifuge to completely stop before opening the top cover, unscrew the fixing screws, and remove the adapter. If the centrifugation is not complete, repeat the above steps until the centrifugation requirements are met

 


5. Alarm Prompt

image.png 

When you click start, if the instrument detects an unbalanced rotor, this interface will pop up and the experiment will be stopped.

Once this interface appears, there will be continuous alarm sounds until you click "OK" to dismiss it.

 


6. Breathing Light Prompt Comparison Table

No.

Instrument Status

Breathing Light Color

Breathing Light State

1

Self-test

 Magenta

Fast breathing

2

Fault

 Red

Steady on

3

Standby

Green

Breathing

4

Door not closed properly 

Yellow

Fast breathing

5

Acceleration

 Blue 

Flowing

6

Deceleration

 Blue 

Flowing

7

 Arrival at specified speed

 Blue

Steady on

8

Rapid cooling

 Cyan

Flowing

9

Rapid cooling reaches standard

 Cyan

Steady on

10

Instant centrifugation

 White

Flowing

 


Comparison of Rotation Speed and Centrifugal Force

image.png 

 

n(rpm)

RCF(g)

1000

95.03

2000

380.12

3000

855.27

4000

1520.48

5000

2375.75

6000

3421.08

7000

4656.47

8000

6081.92

9000

7697.43

10000

9503

11000

11498.63

12000

13684.32

13000

16060.07

14000

18625.88

15000

21381.75

16000

24327.68

17000

27463.67

18000

30789.72

19000

34305.83

20000

38012

 


Equipment Maintenance

1. If solvents or salt water, acidic or alkaline solutions are spilled on the low-temperature centrifuge, use a soft cloth dampened with water to wipe them clean immediately to avoid damage to the instrument.

2. Make sure to turn off the power and unplug the power cord before cleaning.

3. Do not perform high-pressure sterilization on any part of the low-temperature centrifuge, including the adapter.

4. The components of the adapter should be cleaned after use. Use appropriate cleaning agents, rinse with distilled water, and then dry with paper towels.

5. After using suitable cleaning agents, wipe the low-temperature centrifuge clean with a soft cloth.

6. Recommended disinfectants and cleaning agents for cleaning the low-temperature centrifuge and adapter include:

a. General cleaning agent

b. Neutral detergent

c. 70% alcohol

 


Standard Adapter

07.jpg(2 mL × 24)


 

 

 

 

https://www.servicebio.com/goodsdetail?id=97283