ตู้ชีวนิรภัย คลาส 2 (IoT function) (BIOLOGICAL SAFETY CABINET TOUCH SCREEN)

คุณสมบัติสินค้า:

SKU :

ปริมาณสินค้า (Quantity)

หมวดหมู่ : 12. Lab Equipment Refrigerator & Freezer Haier

แบรนด์ : Haier (China)

Share

Biological Safety Cabinet (Touchscreen)

The X series of standard Class II microbiological safety cabinets are suitable for basic cell biology, microbiology, biomedicine, biosafety laboratories and other laboratories. It is the most basic protection and isolation equipment for biosafety.

Product Features

Dual DC Fans
The dual DC fans meet the low-noise, energy-saving and high-reliability requirements

Utilizing Intelligent Constant Air Speed Design to Monitor the Downward Airflow and the Inlet Airflow in Real-Time.
The dual air speed sensors adjust the fan speed through a microcomputer system so as to maintain constant air speed inside the cabinet

Adopting Ultralow Penetration Air Filters (ULPA)
Ensuring a cleanness grade conforming to Class 1 of the American standard FED STD 209E (Class 3 of IS014644-1) and using pressure sensors to monitor the service life of the filters in real-time to ensure superior accuracy and efficiency

Adopting an Intelligent Interlock Design to Avoid the Risk of Disoperation;
With an Operational Front Window Interlocking with the UV Lamp, LED Lamp and Fan Intelligently to Ensure Better Security

One-button UV Lamp Timer
Enabling the memory setting of the user's UV lamp usage habits for convenient one-key start-up of the UV lamp timing function

 

Specifications

ModelDescription
HR1200-IIA2-XPower Supply (V/Hz):220/60; 220/50; Power of Blower (W):DC 120 112; Downflow Velocity (m/s):0.3; Exhaust Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Main Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Airflow Circulation:70% Downflow, 30% Exhaust; Size(Width):1336mm; Blowers:Dual; Sash Opening:1230mm
HR1500-IIA2-XPower Supply (V/Hz):220/60; 220/50; Power of Blower (W):DC 190 112; Downflow Velocity (m/s):0.33; Exhaust Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Main Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Airflow Circulation:70% Downflow, 30% Exhaust; Size(Width):1636mm; Blowers:Dual; Sash Opening:1530mm
HR1800-IIA2-XPower Supply (V/Hz):220/60; 220/50; Power of Blower (W):DC 120 112; Downflow Velocity (m/s):0.3; Exhaust Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Main Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Airflow Circulation:70% Downflow, 30% Exhaust; Size(Width):1936mm; Blowers:Dual; Sash Opening:1830mm

 

https://www.haiermedical.com/biological-safety-cabinet/biological-safety-cabinet-touchscreen.html