Vertical Mixer

Attribute:

SKU : SMV-P

Brand : Servicebio

Share

 Product Introduction

The vertical mixer is suitable for general mixing scenarios in industries such as biology, medicine, and chemicals. It can be put into the refrigerator or incubator.

 


Product Features

 

1. Rotary operation for gentle and thorough mixing;

2. Adjustable speed range: 10-80rpm;

3. Accurate speed control;

4. Low noise;

5. Various sizes of clamps can be freely combined, suitable for 1.5mL, 2.0mL, 5mL, 10mL, 15mL, and 50mL centrifuge tubes;

6. Memory function: The startup parameters are the last settings before the previous shutdown.

7. Can be placed in refrigerators or incubators.

8. Application scenarios: Experiments such as IP, Co-IP, CHIP, protein and antibody purification, extraction, tissue culture, blood sample anticoagulation, latex turbidity, etc.


Product Parameters

Product NameVertical Mixer
Environmental temperature5°C~40°C
Relative humidity80%
Input powerAC100V~AC240V
AC power50 Hz/60 Hz
Output power24 V,1.5 A, 36 W
Motor typeStepper motor
Speed range10-80 rpm
Time range1m-99h59m
Speed displayDigital display
Operating modeContinuous mode
Voltage100-240 V,50/60 Hz
Input power36 W
Dimensions395×90×136 mm
Product weight1.77 Kg

 


Machine Description

1. Structural Diagram 


image.png

2. Optional Accessories

                     ModelDescription
Standard AdapterSMV-P-A8×1.5(2.0)mL+4×5mL+8×15(10)mL+4×50mL
Optional Adapter
SMV-P-B12×1.5(2.0)mL+8×15(10)mL+4×50mL
SMV-P-C40×1.5(2.0)mL
SMV-P-D40×5mL
SMV-P-E18×15(10)mL
SMV-P-F12×50mL
SMV-P-G6×15(10)mL+8×50mL
SMV-P-H4×Microplate(96 Deep Well Plate,PCR Plate, ELISA Plate) 

If you need to customize other models or modules, please contact the supplier

3. Installation Instructions

1. Ensure a good working environment, free from explosive and flammable materials.

2. Open the package and check whether the instrument accessories are complete, then place the instrument on a horizontal workbench.

3. If multiple instruments are used at the same time, please maintain a distance of more than 25cm between each equipment.

4. Before connecting the instrument to the power supply, please ensure that the input voltage meets the product standard.

5. Before installing the accessories, first turn off the power, gently remove the original accessories, and then connect the replacement accessories with screws. Before each use of the instrument, please confirm that the instrument and its accessories are not damaged.

 


Operation Guide

 

image.png


1. Place the instrument on a stable. level workbench, Connect the power supply and turn on the power switch

2. Touch the "Function switch" button to select the parameter you want to set. The selected parameter will blink. Use the

"Increase" or " Decrease" buttons to set it to the desired value.

3. Once the value is set, touch the"Start/Stop" button to start the instrument.

4. The instrument allows adjusting the speed during operation. lf you need to adjust the time, you must pause the instrument

first and then use the function switch button to set.

5. If you need to replace the adapter, unscrew the hand-twist screws and move the entire adapter toward the shaft sleeve.

then lift it out at an angle. When replacing, first pass the long shaft through the shaft sleeve. lf the travel is not enough, pul

the base slightly outward to facilitate the shaft entering the connecting sleeve, Align the holes and tighten the screws to

secure it.

6. When taking or placing centrifuge tubes, please ensure the instrument is in a stopped state. lf the instrument becomes

jammed due to improper operation, the instrument should be paused and then restarted to resume operation.

 


Standard Adapter

SMV-P-A-2(1).jpg

 

(SMV-P-A 8×1.5(2.0)mL+4×5mL+8×15(10)mL+4×50mL)


 

 


https://www.servicebio.com/goodsdetail?id=72718