SKU :
ปริมาณสินค้า (Quantity)
Categories : 12. Lab Equipment ,  Pharmacy Refrigerator ,  Haier , 
Brand : Haier (China)
Share
Biological Safety Cabinet (Touchscreen)
The X series of standard Class II microbiological safety cabinets are suitable for basic cell biology, microbiology, biomedicine, biosafety laboratories and other laboratories. It is the most basic protection and isolation equipment for biosafety.
Product Features
Dual DC Fans
The dual DC fans meet the low-noise, energy-saving and high-reliability requirements
Utilizing Intelligent Constant Air Speed Design to Monitor the Downward Airflow and the Inlet Airflow in Real-Time.
The dual air speed sensors adjust the fan speed through a microcomputer system so as to maintain constant air speed inside the cabinet
Adopting Ultralow Penetration Air Filters (ULPA)
Ensuring a cleanness grade conforming to Class 1 of the American standard FED STD 209E (Class 3 of IS014644-1) and using pressure sensors to monitor the service life of the filters in real-time to ensure superior accuracy and efficiency
Adopting an Intelligent Interlock Design to Avoid the Risk of Disoperation;
With an Operational Front Window Interlocking with the UV Lamp, LED Lamp and Fan Intelligently to Ensure Better Security
One-button UV Lamp Timer
Enabling the memory setting of the user's UV lamp usage habits for convenient one-key start-up of the UV lamp timing function
Specifications
Model | Description |
HR1200-IIA2-X | Power Supply (V/Hz):220/60; 220/50; Power of Blower (W):DC 120 112; Downflow Velocity (m/s):0.3; Exhaust Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Main Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Airflow Circulation:70% Downflow, 30% Exhaust; Size(Width):1336mm; Blowers:Dual; Sash Opening:1230mm |
HR1500-IIA2-X | Power Supply (V/Hz):220/60; 220/50; Power of Blower (W):DC 190 112; Downflow Velocity (m/s):0.33; Exhaust Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Main Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Airflow Circulation:70% Downflow, 30% Exhaust; Size(Width):1636mm; Blowers:Dual; Sash Opening:1530mm |
HR1800-IIA2-X | Power Supply (V/Hz):220/60; 220/50; Power of Blower (W):DC 120 112; Downflow Velocity (m/s):0.3; Exhaust Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Main Filter Typical Efficiency:ULPA,U15,99.9995%@0.12um; Airflow Circulation:70% Downflow, 30% Exhaust; Size(Width):1936mm; Blowers:Dual; Sash Opening:1830mm |
https://www.haiermedical.com/biological-safety-cabinet/biological-safety-cabinet-touchscreen.html